5LB R410A Refrigerant – Product Overview
R410A is a near-azeotropic HFC refrigerant used in compatible air conditioning, heat pump, chiller, and selected refrigeration equipment designed specifically for R410A. This 5 lb R410A refrigerant cylinder offers a convenient size for professional HVAC service, maintenance, repairs, and smaller refrigerant requirements.
Key Benefits
- Convenient 5 lb R410A refrigerant cylinder
- For equipment specifically designed and labeled for R410A
- Suitable for compatible residential and commercial air conditioning systems
- Used in approved heat pumps, chillers, and HVAC equipment
- Practical size for service, maintenance, and smaller HVAC jobs
Compatibility Notice
Use R410A only in equipment specifically designed for R410A. R410A operates at substantially higher pressures than R22 and must not be used in R22, R32, R454B, or other incompatible systems. Always verify the equipment nameplate and manufacturer specifications before purchase or service.

Key Specifications
- Refrigerant
- R410A refrigerant blend
- Molecular Formula
- 50% R32 + 50% R125
- Net Weight
- 25 lb (11.3 kg)
- Purity
- ≥ 99.80%
- Cylinder
- Pressure-resistant steel
Full Technical Data
View Full Size
Shipping
- $30 shipping per cylinder
- Ships within 24 business hours
- Estimated delivery: 2–5 business days
- Ships from the United States
- Tracking provided after dispatch
| 1 Cylinder | $30 |
|---|---|
| 2 Cylinders | $60 |
| 3 Cylinders | $90 |
Returns
- 30-day return request window
- Unused and unopened cylinders only
- Original condition and packaging required
- Contact support before returning regulated goods
- Refunds issued after inspection
Important R410A 5 lb Product Information
5 lb R410A refrigerant for air-conditioning and heat-pump equipment specifically designed for R410A. Use service equipment rated for its operating pressures.
For R410A Equipment Only Check the system nameplate before ordering
R410A operates at higher pressures than R22 and must only be used in equipment designed for R410A.
- R410A is not a drop-in replacement for R22.
- Do not mix R410A with R22, R32, R454B or other refrigerants.
- Follow the equipment manufacturer's charge and lubricant specifications.
Purchaser and Service Requirements Confirm eligibility for stationary refrigerant use
Confirm purchaser eligibility under EPA refrigerant-sales rules before ordering this 5 lb cylinder.
- Stationary refrigerant purchases and service are subject to applicable Section 608 requirements.
- A Section 609 automotive certification alone does not cover stationary refrigerant use.
- Use trained personnel and recover refrigerant rather than releasing it.
5 lb R410A Cylinder Net refrigerant weight, not total shipping weight
This product is the 5 lb (approximately 2.27 kg) R410A size. Net refrigerant weight excludes the cylinder and packaging.
- Check the product label, valve, seal and cylinder condition before use.
- Do not use a damaged, leaking or altered cylinder.
- Verify the valve connection and required equipment before starting service.
R410A-Rated Service Equipment Use tools and recovery equipment rated for R410A pressures
Use compatible manifold gauges, hoses, recovery machines and recovery cylinders designed for R410A service.
- Do not assume tools intended for R22 have a suitable pressure rating.
- Follow manufacturer instructions for liquid withdrawal and controlled charging of this blend.
- Charge to the equipment specification and complete the required leak and operating checks.
Storage and Before Ordering Protect the cylinder and review the product details
Store upright and secured in a cool, dry, well-ventilated location. Follow the cylinder label and product Safety Data Sheet (SDS).
- Protect the cylinder from excessive heat, direct sunlight and physical damage.
- Confirm R410A, 5 lb net weight and the intended equipment before ordering.
- Review the store shipping and return policies, and use the SDS for handling precautions.
Not sure whether your equipment uses R410A? Send support a photo of the system nameplate and model number to help identify the specified refrigerant.
FAQ
Is R410A compatible with my system?
Use R410A only in systems designed and labeled for R410A. It operates differently from R22 and must not be mixed with R22, R32, R454B, or another refrigerant. Before purchasing, check the equipment nameplate and manufacturer documentation. If you are unsure, send us a clear photo of the nameplate and consult a qualified technician.
What is R410A commonly used for?
R410A refrigerant blend is intended for compatible R410A air-conditioning, heat-pump, and HVAC equipment. The listed applications are general guidance only; the equipment nameplate and manufacturer specification determine the correct refrigerant.
How much refrigerant is included in the R410A cylinder?
The cylinder contains 25 lb (11.3 kg) net weight of R410A refrigerant. Net contents do not include the cylinder tare weight or outer packaging. Verify the product label, seal, and cylinder condition when the shipment arrives.
Can I mix R410A with another refrigerant or use it as a drop-in replacement?
No. Refrigerants are not interchangeable and should not be mixed. Use only the refrigerant approved for the equipment. Any conversion or retrofit must follow the equipment or retrofit manufacturer's written requirements and be completed by a qualified professional.
Do I need a certified technician to handle R410A?
R410A is a high-pressure refrigerant. Service requires appropriate recovery and charging equipment and should be performed by a qualified HVAC professional. Purchasing, handling, recovery, transport, and installation requirements may vary by product, application, and location. Confirm the rules that apply to you before ordering or using the product.
What are the shipping cost and delivery time for R410A?
Shipping is $30 per cylinder and updates with quantity. Orders ship from the United States within 24 business hours, and estimated delivery is 3–5 business days. Tracking is provided after dispatch. Carrier and hazardous-material restrictions may apply.
What should I do if the R410A cylinder arrives damaged or appears to leak?
Do not use the cylinder if it is leaking, the valve is damaged, or the package appears unsafe. Keep it away from heat, flames, and occupied indoor areas, and do not attempt a repair. Contact support with the order number and clear photos of the cylinder, valve, damage, packaging, shipping label, and batch code so the issue can be reviewed.
Can I return an unopened R410A cylinder?
A return must be requested within 30 days. Only unused, unopened cylinders in their original condition and packaging are eligible. Contact support for approval before returning regulated goods. Specialized carrier requirements may apply, return shipping costs are the customer’s responsibility, and refunds are issued after inspection.
Do you offer bulk pricing for R410A?
Bulk pricing may be available depending on quantity, destination, inventory, freight requirements, and applicable shipping restrictions. Send the required quantity, cylinder size, delivery ZIP code or country, company details, and requested delivery date for a confirmed quotation.