Product Overview
R407A is a zeotropic HFC blend used in compatible medium- and low-temperature refrigeration systems. This 25 lb cylinder is suitable for professional service of new equipment and approved retrofits replacing R404A or R507A.
Key Benefits
- 25 lb R407A refrigerant cylinder
- For medium- and low-temperature refrigeration
- Suitable for compatible supermarket refrigeration
- Used in approved food storage and transport systems
- Designed for professional refrigeration maintenance
Compatibility Notice
Use R407A only in equipment labeled for R407A or in a manufacturer-approved conversion. Do not mix R407A with R404A, R407C, R507A or another refrigerant. System controls and components must be checked before retrofit.

Key Specifications
- Refrigerant
- R407A refrigerant blend
- Molecular Formula
- Refrigerant blend
- Net Weight
- 25 lb (11.3 kg)
- Purity
- ≥ 99.80%
- Cylinder
- Pressure-resistant steel
Full Technical Data
View Full Size
Shipping
- $30 shipping per cylinder
- Ships within 24 business hours
- Estimated delivery: 2–5 business days
- Ships from the United States
- Tracking provided after dispatch
| 1 Cylinder | $30 |
|---|---|
| 2 Cylinders | $60 |
| 3 Cylinders | $90 |
Returns
- 30-day return request window
- Unused and unopened cylinders only
- Original condition and packaging required
- Contact support before returning regulated goods
- Refunds issued after inspection
Important R407A Product Information
R407A is an A1 zeotropic refrigerant blend used in compatible commercial refrigeration and approved retrofit applications.
Confirm R407A Compatibility Use only in an approved R407A system or retrofit
R407A is commonly used in commercial refrigeration, but equipment compatibility must be confirmed before charging.
- Do not add R407A directly on top of R22, R404A, or another refrigerant.
- A retrofit may require oil, seal, control, and expansion-device changes.
- Record the completed refrigerant conversion on the equipment label.
Professional Blend Handling Use qualified technicians and approved recovery equipment
Stationary refrigeration work should be performed by appropriately EPA Section 608-certified personnel.
- Recover the existing charge completely before conversion.
- Evacuate, leak-test, and weigh in the specified charge.
- Do not intentionally vent refrigerant.
25 lb R407A Cylinder Factory-filled zeotropic refrigerant blend
The cylinder contains 25 lb (11.3 kg) net weight of R407A. Inspect the label, valve, seal, and cylinder before use.
- Keep the cylinder upright and secured.
- Do not use a damaged or leaking cylinder.
- Confirm the required charge quantity and valve connection.
Charge as Liquid Maintain blend composition and account for temperature glide
Transfer R407A from the cylinder in the liquid phase and use dew-point or bubble-point data as appropriate.
- Meter liquid safely to prevent compressor damage.
- Account for temperature glide during superheat and subcooling checks.
- Do not mix with another refrigerant.
System Setup and Storage Verify oil, controls, labeling, and cylinder protection
Follow the equipment or retrofit manufacturer's instructions and the product Safety Data Sheet.
- Confirm lubricant compatibility and operating setpoints.
- Store the cylinder in a cool, dry, ventilated area.
- Review the Shipping & Returns tab before ordering.
Planning an R407A retrofit? Send support the current refrigerant, equipment model, application, and operating temperature range.
FAQ
Is R407A compatible with my system?
Use R407A only when the equipment manufacturer or an approved retrofit specification calls for R407A. Do not add it directly on top of R22, R404A, or another refrigerant. Before purchasing, check the equipment nameplate and manufacturer documentation. If you are unsure, send us a clear photo of the nameplate and consult a qualified technician.
What is R407A commonly used for?
R407A refrigerant blend is intended for compatible commercial refrigeration and low-temperature equipment. The listed applications are general guidance only; the equipment nameplate and manufacturer specification determine the correct refrigerant.
How much refrigerant is included in the R407A cylinder?
The cylinder contains 25 lb (11.3 kg) net weight of R407A refrigerant. Net contents do not include the cylinder tare weight or outer packaging. Verify the product label, seal, and cylinder condition when the shipment arrives.
Can I mix R407A with another refrigerant or use it as a drop-in replacement?
No. Refrigerants are not interchangeable and should not be mixed. Use only the refrigerant approved for the equipment. Any conversion or retrofit must follow the equipment or retrofit manufacturer's written requirements and be completed by a qualified professional.
Do I need a certified technician to handle R407A?
System conversion or charging decisions should be made by a qualified refrigeration professional after checking the equipment, lubricant, controls, and manufacturer requirements. Purchasing, handling, recovery, transport, and installation requirements may vary by product, application, and location. Confirm the rules that apply to you before ordering or using the product.
What are the shipping cost and delivery time for R407A?
Shipping is $30 per cylinder and updates with quantity. Orders ship from the United States within 24 business hours, and estimated delivery is 3–5 business days. Tracking is provided after dispatch. Carrier and hazardous-material restrictions may apply.
What should I do if the R407A cylinder arrives damaged or appears to leak?
Do not use the cylinder if it is leaking, the valve is damaged, or the package appears unsafe. Keep it away from heat, flames, and occupied indoor areas, and do not attempt a repair. Contact support with the order number and clear photos of the cylinder, valve, damage, packaging, shipping label, and batch code so the issue can be reviewed.
Can I return an unopened R407A cylinder?
A return must be requested within 30 days. Only unused, unopened cylinders in their original condition and packaging are eligible. Contact support for approval before returning regulated goods. Specialized carrier requirements may apply, return shipping costs are the customer’s responsibility, and refunds are issued after inspection.
Do you offer bulk pricing for R407A?
Bulk pricing may be available depending on quantity, destination, inventory, freight requirements, and applicable shipping restrictions. Send the required quantity, cylinder size, delivery ZIP code or country, company details, and requested delivery date for a confirmed quotation.